HgCalc is used with your imported XC-6000 MercSampler sample run data, then the trap analysis data is entered, and the application calculates the Hourly, Daily, Weekly, and Yearly total mercury mass in micro-grams, grams and pounds and total mercury emissions as specified in 40CFR Part 75.
HgCalc also verifies QA/QC specifications regarding section 2 breakthrough, calculates normalized HG mass also HG concentration, checks relative deviation, and section 3 spike recovery as shown in 40CFR Part 75 Appendix K table K-1
This is a sample of HgCalc using a 1 hour proportional run on an XC-6000 MercSampler system.
The .csv data was imported into the HgCalc application from the XC-6000, and then the lab data for each trap section & spike recovered from analysis is entered.
Total Stack Volume is shown under Run Data field as recorded by the XC-6000 MercSampler if 4-20 external flow was connected or Modbus interface was connected and flow data was supplied by the DAS.
For more information,
CLICK HERE to review the new
HgCalc Brochure, email
Shawn Wood, or call 800.882.3214 to discuss HgCalc with us and how it can help you.