We have had a tremendous response to the Utility MATS webinar and want to Thank everyone for participating and attending.
If you were able to join the presentation we hope that you found the information useful. If there are any further details that you need regarding any aspect of air emission sampling, please do not hesitate to contact us.
Once again, many thanks for your interest.
Thank You for your participation!
February 14, 2012 Apex is pleased to offer a complimentary webinar outlining the emission testing Requirements of the Mercury Air Toxics Standards (MATS) rule signed by Lisa Jackson, US EPA, on December 16, 2011.
EPA Issues Final MATS
Air Emissions Monitoring for the Mercury Air Toxics Standards
MATS requires the measurement of at least 15 pollutants involving the use of approximate 30 different measurement methods.
We’ve designed this webinar to support the needs of power plant operators and the emission testing firms that serve them. Participants will complete the webinar with an understanding of the emission monitoring requirements associated with the final rule and options for implementing those requirements.
For more information on the rule, please visit: http://www.epa.gov/mats/index.html
Meet the Requirements for the New MACT Industrial / Utility / Cement Standards
PCME Wet Stack 181 Features: The PCME Wet Stack 181 measures particulate emissions from wet scrubbers and other processes where the flue gas falls below the dew point (cold stack conditions) or has water droplet presence.
• Compliance Particulate Monitoring for Wet Stack Conditions (PS-11/EN 1418)
• For Stack Measurement After Flue Gas Desulphurisation (FGD) Plant and Wet Scrubbers
• Includes ProScatterTM PCME QAL 181 Sensor with QAL1 approvals
• Variable Speed Sampling and Optional Automatic Isokinetic Sampling
• Highly Sensitive (<0.1 mg/m3) and Rugged Instrument for Measuring Particulate Concentrations in Wet Flues
• Isokinetic Condition Automatic Adjustment
• Automatic Control and Function Test of all Critical Systems
• Low Maintenance Requirements and no Laborious Service Requirements
• Modular Design to Facilitate Lifting to Stack Location and Ease of Assembly
• QAL1 Approved Light Scatter Probe, Suitable for Monitoring According to EN 14181 and PS-11
• Automatic Zero and Span Drift Check and Manual Audit Functionality
• Powerful User Interface and in Built Data Logging and Recording
More Information on PCME Wet Stack 181
XC-6000EPC Automated MercSampler Features: Sorbent Trap Monitoring System is designed for continuous sampling of vapor-phase mercury emissions from stationary combustion sources.
• Fully Automated Paired Sampling
• Dual Mass Flow Sensors
• Proportional or Constant Flow Control
• Accepts External Analog Signal for Proportional Flow Control
• Dual Gas Meters with Optical Encoders (1cc resolution)
• Barometric Pressure Transducer
• Dual Long Life Brushless Compact DC Pumps
• Internal Flash Memory Stores 99 Test Runs
• Custom Data Acquisition Control Board
• RISC Based Micro Controller Technology
• 14 bit A/D Converter
• Eight 15KV Isolated Type K TC Channels
• External Inputs: Moisture Analyzer, Stack Flow, Remote Pause
More Information on XC-6000EPC Automated MerSampler