HAVE A QUESTION? CALL US!
(800) 882-3214

XCF-170 Digital Method 17 Sampling Console

XC-170 - Method 17 Sampling Console

XCF-170 Digital Method 17 Sampling Console

Smaller. Lighter. Easier.

The new XCF-170 Digital Source Sampling Console is the first model being offered in our new compact light weight design.

The console uses an internal diaphragm pump, reducing the weight of the console and pump portion of the train to 37lbs, from 74 lbs (a 50% reduction).

Clear
SKU: XCF-170 Full Flow Console

Description

The new XCF-170 Digital Source Sampling Console is the first Method 17 console being offered in our new compact light weight design. This console is manufactured in the United States and meets US EPA Method 17, CFR 40 part 60 standards.

The XCF-170 combines the reliability of our manual consoles with the convenience of digital components.

The console uses an internal diaphragm pump, reducing the weight of the console and pump portion of the train to 37lbs.

The new Digital Display is backlit, sunlight readable and transflective. The unit contains two high resolution, digital low pressure sensors. The displays allows for easy zeroing, dampening adjustment, input power filtering, and measurement unit selection.

The XCF-170 will assure you ease of use and accurate results, giving you extra confidence during your sampling test.

Features and Benefits:

  • Smaller and Lighter Console
  • Rugged Durable Case
  • No messy manometer fluid headaches
  • Reliable, Accurate Results
  • Precision Gas Meter with Mechanical Index
  • Easily replaceable Dual Pressure Transducers
  • Sunlight Readable Display
  • Option to Select between Metric or Imperial
  • Digital Display for TC Temperatures, ΔP, ΔH, and Gas Meter Volume
  • Carrying Strap and 3 Handles on Case
  • Internal Diaphragm Sampling Pump

Specifications:

Display:
4×20 Character Back-lit Transflective Liquid Crystal Display with digital operation of timer, delta P, delta H and Temperature

Display Control:
Momentary push button switch control for display operation and setup.

Gas Meter:
Model SK25EX, with 100 CPR Quadrature Encoder, 0.7L/rev., 41 lpm max.

Flow Indicator:
Precision Machined Stainless Steel Orifice with Pressure Transducer,
Range 0 – 5” H2O (0 – 1245 Pa) resolution of 0.01” (1 Pa).

Temperature Measurement:
5 channel individually isolated Type-K thermocouple meter,
°C/°F selectable, -200°C to 1372°C range. (-328°F to 2502°F).

Digital Pressure Transducers:
ΔP +/-5.0” (+/- 1245 Pa) Range Bi-Directional with 0.001” (1 Pa) Resolution
ΔH +/-5.0”  (+/-1245 Pa) Range Bi-Directional with 0.01” (1 Pa) Resolution

Vacuum Gauge:
Dual Scale, 0 to 30” Hg and 0 to 100kPa.

Umbilical Connection:
Sample Inlet: 1/4” Stainless Steel Full Flow Quick-Connect.
Pitot Connections: 1/8” Stainless Steel Full Flow Quick-Connects
TC Connections: AUX, STACK, PROBE,EXIT

Power:
Pump Power Supply: 110V, 150W, 24V/6.3A, IEC C-14 Inlet.
Display Power Supply: 15W, 12VDC

Dimensions: H17” x W17” x D12” (57 cm x 33.5 cm x 61 cm).

Weight: 37 lbs (9.98kg)


Special Back Half  Leak Check Consideration:

For metering systems having diaphragm pumps, the normal leak-check procedure will not detect leakages within the pump. For these cases, the following leak-check procedure is suggested: make a 10-minute calibration run at 0.00035 cubic meters per minute (0.02 cubic feet per minute); at the end of the run, take the difference between the measured wet test meter and the dry gas meter volumes; divide the difference by 10, to get the leak rate. The leak rate should not exceed 0.00057 cubic meters per minute (0.02 cubic feet per minute). [Section No. 3.4.2, Page 5 of 22, Quality Assurance Handbook by EPA, 1980 Version]