PM CEMS Wet Stack 181 · Measuring Particulate Emissions from Wet Scrubbers

The system uses an advanced ProScatterTM light scatter sensor (PCME QAL 181) which is certified by TUV and MCERTS as QAL1 compliant. With certification ranges covering both 0-15 mg/m3 and 0-100 mg/m3 dust levels, the sensor is suitable for monitoring the highly abated emissions found after Flue Gas Desulphurisation Plant (FGD). The instrument is able to monitor a saturated flue gas which is critical for the application of monitoring emissions from a coal fired power plant fitted with a wet FGD system and meets the requirements of PS-11 and EN 14181.

The system will also operate reliably in the flue gas conditions found after wet collectors in the Pulp and Paper, Metal and Chemicals industry where particulate levels are higher and the instrument is able to cope with potentially more contaminating conditions.

Key advantages of the instrument are as follows:

   Highly sensitive (<0.1 mg/m3) and rugged instrument for measuring particulate
    concentrations in wet flues

   Isokinetic condition automatic adjustment [requires input from external flow meter (option)

   Automatic control and function test of all critical systems (vaporising chamber,
    light scatter unit and sampling pump)

  Low maintenance requirements and no laborious service requirements

  Modular design to facilitate lifting to stack location and ease of assembly

  QAL1 approved light scatter probe, suitable for monitoring according to
    EN 14181 and PS-11

  Automatic zero and span drift check and manual audit functionality

  Powerful user interface and in built data logging and recording Isokinetic Sampling (option)

Process and Application Conditions

The system may be used as a particulate CEM in the following applications:

• Flue Gas Desulphurisation (FGD) after coal and oil fired power plant.
• Waste Incineration plant with wet scrubbing abatement plant.
• Pulp and Paper Recovery boilers.
• Metallurgical and chemical processes fitted with wet scrubbers.
• Sugar beat dryers/boilers with high moisture in flue gas.
• Particle board and fibre drying.

The instrument is suitable for the following process and stack conditions:

• PS-11 measurement range 0-15, 0-100 mg/m3
• QAL1 Certification range (181 sensor) 0-15, 0-100 mg/m3
• Detection Limit <0.1 mg/m3
• Max stack temp: 300oC
• Flue gas: below dew point
• Heater power: 3kW (maximum)
• Flue Gas velocity range 1-20m/s